TitleProduct

Induction Electric Generator Withstand Resonance Test

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Hubei

  • Validity to:

    Long-term effective

  • Last update:

    2020-10-28 14:07

  • Browse the number:

    336

Send an inquiries

Company Profile

Wuhan Guodianzhongxing Electrical Power Equipment Co., Ltd

By certification [File Integrity]

Contact:gdzx888(Mr.)  

Email:

Telephone:

Phone:

Area:Hubei

Address:Hubei

Website:http://www.highvoltage-test.com/ http://gdzx888.ttspfs.com/

Product Details

Output voltage:

≤0~60kV(AC RMS)

Output frequency:

50Hz

High Light:

ac resonant test system, resonance test series




Inductance Adjustable High Voltage Resonant Test System for Generator Alternator

Features

1.As the resonant system is reactive power full compensated, the power of the equipment and power source is only less than 1/10 of measured equipment; with smaller volume and lighter weight compared with the equipment in same capacity. The device with large output capacity and small power supply capacity, low cost, easy to operate and safe.

2.Serial resonant system actually is current filter circuit, which make the tested equipment through current almost being fundamental current, the output voltage distortion (THD) is very small, better than current AC voltage withstand equipment.

3.The short circuit current after flash-over or breakdown is only less than 1/10 (1/Q) of the test current before the short-circuit, which can effectively prevent further damage to fault point after breakdown.

4.Auto blowout the arc after flash-over, which is a long and stable process to recover the serial resonant voltage, so it is very safe.


Technique Parameter:

Rated output voltage

≤0~60kV(AC effective value)

Output frequency

50Hz

Resonate voltage waveform

Sine wave, distortion ≤1%

Working mode

Full power continuous working time: 1min

Quality factor

10~40

Maximum measured capacity

≤3000kVA

Power supply

380V±15%, frequency:50Hz

Serial product and application

Model

Application (AC voltage withstand test for generator with output voltage ≤20kV, frequency: 50Hz±2Hz)

Control cabinet

Reactor

Excitation transformer

Divider

Application

ZXGXZ-100/50

10kW/220V

50kV/1A 2 sets

10kW/5kV

50kV/500pF

Generator 0.07~0.13uF 10kVcable(300mm2)≤1.0km

ZXGXZ-150/50

15kW/380V

50kV/1.5A 2 sets

15kW/5kV

Generator 0.13~2uF 10kVcable(300mm2)≤1.5km

ZXGXZ-225/50

25kW/380V

50kV/1.5A 3 sets,

25kW/5kV

Generator 0.2~0.27uF 10kVcable(300mm2)≤2.5km

ZXGXZ-350/50

30kW/380V

60kV/2A 3 sets

30kW/5kV

Generator 0.27~0.33uF

Note: make the solution according the measured equipment.

Capacitance Reference table of common use Generators:

Category

Generator

MODEL#

Rated capacity MW

Rated Voltage kV

Phase Capacitance:μF

Fire Power Generator

T2-12-2

12

6.3

0.1

TQ-25-2

2

6.3

0.19

TBC-30

30

6.3

0.2

TB2-30-2

30

6.3

0.2

TQN-50-2

50

10.5

0.209

TB-50-2

50

10.5

0.26

TB-60-2

60

10.5

0.25

TQN-100-2

100

13.8

0.234

WT23S-083AF3

300

15

0.29

TB-320-2

320

20

0.3

T264/640

600

20

0.368

QF-30-2

30

6.3

0.1

QF-60-2

60

6.3

0.234

QF-60-2

60

10.5

0.33

QFS-125-2

125

13.8

0.08~0.12

QFSN-200-2

200

15.75

0.19~0.21

QFQS-200-2

200

15.75

0.1928~0.21

QFS-300-2

300

18

0.16~0.2

QFSN-300-2

300

18

0.18~0.2

QFSN-600-2

600

20

0.234

GE ATB-2

352

23

0.268

TBB-200-2

200

15.75

0.107

TBB-500-2

500

20

0.25

TBB-320-2

320

20

0.31

TBB-800-2

800

24

0.25

Westinghouse2-105*234

600

20

0.2

ABB 50WT23E-138

600

22

0.253

Synchronous condenser

TT-15-8

15

6.6

0.108

TT-30-6

30

10.5

0.2


Tag:

AC resonant test system, hipot test equipment, resonance test series


http://www.highvoltage-test.com/